Space
In this section all space realted information needed to satisfy the Exchange Energy Analysis Model (Energy) will be described.
Loads
Specify the load information for the space.
| Information Needed | Man | Opt | Rec | Actor Supplying | Functional Part |
|---|---|---|---|---|---|
| Source of the load. Load source may be people, lighting, equipment (sensible), ventilation indoor air, ventilation outside air, re-circulated air, exhaust air, air exchange rate, dry bulb temperature, relative humidity, infiltration (sensible). Depending on the source, the maximum and minimum values have to be interpreted. | |
Energy and Comfort Advisor | Define Space Thermal Load (FP) | ||
| Type of thermal load. Type may be Sensible, Latent, Radiant. | |
Energy and Comfort Advisor | Define Space Thermal Load (FP) | ||
| Source of the load properties. Source may be Design, Design Maximum, Design Minimum, Simulated, As Built, Commissioning, Measured. Several sources may be defined for a space. | |
Energy and Comfort Advisor | Define Space Thermal Load (FP) | ||
| Maximum thermal load value. If this value is less than zero (negative), then the load is a loss from the spatial structure. If the value is greater than zero (positive), then the load is a gain to the spatial structure. If the minimum value is not specified, then this value is the actual value. At least one of the maximum, minimum, or time series values must be specified. | |
Energy and Comfort Advisor | Define Space Thermal Load (FP) | ||
| Minimum thermal load value. If this value is less than zero (negative), then the load is a loss from the spatial structure. If the value is greater than zero (positive), then the load is a gain to the spatial structure. | |
Energy and Comfort Advisor | Define Space Thermal Load (FP) | ||
| Time series of the thermal load values. | |
Energy and Comfort Advisor | Define Space Thermal Load (FP) | ||
| Percentage of use requirement or criteria applicable. | |
Energy and Comfort Advisor | Define Space Thermal Load (FP) |