Log In   View a printable version of the current page.
Exchange Energy Analysis Model - Demand (ER)
Added by Kjetil Espedokken, last edited by Jeffrey Wix on Feb 10, 2007  (view change)
Labels: 
er


Exchange Energy Analysis Model (Demand)

Please ensure that you have read the Process Map (PM) named Energy Analysis (PM) before proceeding with this exchange requirement.

The scope of this exchange requirement is the exchange of information about energy demand and comfort. The purpose of the exchange requirement is to enable coordination of energy analysis with HVAC and electrical and piping systems engineers for system definition and sizing.
The exchange requirement assumes that the information provisions outlined in the exchange requirement er_exchange_energy_analysis_model(zones) have been satisfied. This is considered to provide all information required concerning:

  • the building, its location, composition, overall shape and orientation
  • the shape and location of adjacent buildings
  • building storeys within the building
  • spaces within the building including their identification by type, name and function
  • building elements used and their construction type
  • space boundaries that define the relation between spaces and building elements
  • technical systems and their locations for use within energy analysis.

Note that this exchange requirement describes a 'voluntary' coordination point or interaction between the different roles on a project. It does not represent a hard or soft gate for the project.

Information Requirements

Context Description
Precursor In this section all precursor realted information needed to satisfy this Exchange Requirement will be described
Building In this section all building realted information needed to satisfy this Exchange Requirement will be described
Space In this section all space realted information needed to satisfy this Exchange Requirement will be described
Construction In this section all construction realted information needed to satisfy this Exchange Requirement will be described

Results

Type Information Requirements Actor Receiving
Model Energy analysis model containing comfort and peak load information for the building and the spaces within the building.
No content found for label(s) rs_er-exchange-terrain.

Referenced by

This list shows all process maps which reference this specific ER.

1 - Analyze Energy (Programming) - Energy Analysis (PM) (Information Delivery Manual (IDM)) — This process is concerned with determining the comfort, energy demand and energy use of a building based on the initial programming of a project.
Labels: sub-element_energy_analysis_pm, er-exchange-energy-analysis-model-demand, pm-rp-2, pm-rp-3, er-exchange-building-model-programming

Powered by Atlassian Confluence, the Enterprise Wiki. (Version: 2.1.3 Build:#408 Jan 23, 2006) - Bug/feature request - Contact Administrators